Title: Acoustic distortion (microphone) – Audio Lab
---

# Acoustic distortion (microphone)

Harmonic distortion (H2–H10, THD/THD+N) of a driver measured with a microphone, over the band: the same stepped-sine
sweep [THD vs frequency](distortion.html#thd-vs-level-thd-vs-frequency) uses, wired like
[Acoustic response](acoustic-response.html) instead of straight into an electrical device.

## At a glance

| Task | What it tells you | Wiring | Level | A good result |
| --- | --- | --- | --- | --- |
| **Acoustic distortion** | H2–H10, THD/THD+N against frequency, from a microphone | Mono, reference on a rear line input (the electrical loopback), the microphone on a front input (phantom power) | start low (around −30 dBFS) – see *Level and safety* below | a THD curve with no points left off the chart; where it rises, a repeatable rise, not a one-off |

The maths behind this: [Methods → Acoustic distortion (microphone)](methods.html#16-acoustic-distortion-microphone).

## How it works

Exactly [THD vs frequency](distortion.html#thd-vs-level-thd-vs-frequency)'s own stepped sine and harmonic analysis –
one clean tone at a time, so each harmonic (H2–H10) can be told apart from the fundamental, which a chirp's mixed
frequencies could not give cleanly. The only things that differ from the electrical task are the wiring (the
same Y-split reference as Acoustic response and Impedance, no new jig) and two things the electrical task has no
need for: the microphone's own calibration, and marking a step unreliable instead of reporting an impossible
distortion figure from it.

**Microphone calibration applied to each tone, not just the level:** the fundamental, every harmonic and the
noise floor are each corrected by the microphone's own gain at their own frequency before THD/THD+N are
recomputed from the corrected values – not only the displayed level, as a flat level correction alone would be.
A mic with any real slope between a fundamental and its second or third harmonic would otherwise bias the ratio
itself, not just where the curve sits on the page.

**A step too close to the noise floor, or too close to full scale, is left off the chart** rather than kept and
read as a distortion figure – the same way a low-coherence point is left off Acoustic response's or Impedance's
own curve. A driver's acoustic output varies tens of dB with frequency (a resonance, a crossover's presence
peak) far more than most electrical devices do, so one fixed generator level that suits the quietest step can
starve the reading at others, or overload the microphone at the loudest. The status line counts how many steps
this removed; the full, unfiltered figures (including the ones left off the chart) are still in the CSV export,
so nothing is thrown away, only kept off the picture.

Electrical THD vs level keeps both ends of its own sweep on purpose – its own noise floor and its own clipping
*are* the point there – so this filtering applies only here, not to the electrical tasks that share the same
analysis underneath.

## Calibration

- **Microphone calibration** (CALIBRATION panel → MICROPHONE → Import calibration…): a text file of frequency and
  gain pairs (e.g. a Sonarworks XREF export). Audio Lab's own testing used a Sonarworks measuring microphone with
  the calibration file exported from Sonarworks SoundID Reference. See [Device measurements](measured.html) for
  one imported and used in a real run.
- **Loop correction** (ANALYSIS → Save as loop): the electrical reference usually sits on a different kind of
  input than the microphone (a rear line input against a front one with phantom power) – the same fix Acoustic
  response and Gain & phase use for the same reason.
- No jig self-calibration is needed: there is no sense resistor here, nothing to calibrate against a known
  reference.

## Steps

1. Task info (ⓘ) → **Set for a bare driver** or **Set for through an amplifier** – whichever matches what is
   actually connected. Both also set a lower starting generator level than Acoustic response's own default (see
   *Level and safety*).
2. Microphone on a front input (In 1 or In 2): phantom power on at the interface itself, its gain set for a
   clean, unclipped level on the INPUTS meter.
3. Place the microphone the same way as for Acoustic response – see
   [Mounting and distance](acoustic-response.html#mounting-and-distance).
4. ANALYSIS: *Up to harmonic* and *Noise weighting* as for the electrical task; Settings → Sweep sets the
   frequency steps.
5. **RUN.** Before trusting the whole sweep, check the INPUTS meter at the loudest steps (usually a resonance or
   a presence peak, not necessarily 1 kHz) as well as the quietest.

### Level and safety

Start lower than Acoustic response's own default (around −30 dBFS) and raise it only as far as needed – the
generator drives the speaker (or the amplifier feeding it) directly, so an unexpectedly loud level is a real
sound, not just a reading on a meter. A driver's output at its own resonance or a crossover's presence peak can
be tens of dB louder than elsewhere in the same sweep: a level that looks safe at 1 kHz can still overload the
microphone input at the loudest step.

## Limits

- **The microphone's own distortion is not taken out.** The reference-based de-embedding ([THD vs
  frequency](distortion.html#thd-vs-level-thd-vs-frequency)'s *THD − reference*) removes the generator's and the
  amplifier's own distortion, read from the electrical loopback – it says nothing about the microphone, which
  sits only in the acoustic path, not the reference one. A very clean driver reading is still, in part, the
  microphone's own figure.
- **No absolute SPL.** The microphone calibration corrects its own frequency response shape; it is not an
  absolute sensitivity or level calibration of the whole chain. Comparing two drivers' distortion at "the same
  level" means the same generator level and microphone position, not the same dB SPL.
- **THD+N is usually noise-limited here, not distortion-limited.** Even a quiet room is far noisier, relative to a
  modest acoustic output, than the electrical loopback reference – a kept step's THD+N can sit 20–30 dB above its
  THD with the gap explained almost entirely by the fundamental-to-noise-floor distance alone, no real harmonic
  content needed. **Read THD (harmonics only), not THD+N**, as the driver's own distortion figure, unless the
  room is anechoic or the driver is being driven hard enough that noise stops mattering – see
  [Device measurements](measured.html) for a real example.
- **Free air is not an enclosure**, same as Acoustic response: a driver measured free-standing does not
  distortion-test the same way it would installed in its own baffle or box.